Mid-size Data Center (ANSI): 1 MW IT capacity, Tier 3, Chilled Water, Prefab. 15000 ft² - Engineering Package
Reference Design covering data center power supply, cooling & IT space
Published by
Schneider Electric

Mid-size Data Center (ANSI): 1 MW IT capacity, Tier 3, Chilled Water, Prefab. 15000 ft² - Engineering Package
Published by
Schneider Electric
$950
Features
Content
This reference design - Engineering Package contains:
Reference Design 32.pdf
RD32_1.0_Cover_Sheet_EN_R0.pdf
RD32_1.1_Facility_Site_Layout_EN_R0.dwg
RD32_1.1_Facility_Site_Layout_EN_R0.pdf
RD32_2.1_Facility_Power_Overview_EN_R0.pdf
RD32_2.2_Elec_Oneline_EN_R0.dwg
RD32_2.2_Elec_Oneline_EN_R0.pdf
RD32_2.3_Facility_Power_EquipmentList_EN_R0.pdf
RD32_3.1_Facility_Cooling_Overview_EN_R0.pdf
RD32_3.2_Mech_Piping_EN_R0.dwg
RD32_3.2_Mech_Piping_EN_R0.pdf
RD32_3.3_Facility_Cooling_EquipmentList_EN_R0.pdf
RD32_4.1_IT_Space_Overview_EN_R0.pdf
RD32_4.2_IT_Space_EquipmentList_EN_R0.pdf
Scope of application
This reference design is applicable for:
Data Center IT Capacity:
1045 kW
Adaptable from 200 kW to 3135 kW
Target availability:
Tier 3
Annualized PUE at 100% Load:
1.53 in Miami, FL USA
1.31 in Montreal, Canada
1.39 in St. Louis, MO US
Total Racks and Average Density:
110 racks at 9.5 kW/rack
IT & Facility Floor Space:
Min. 14970 ft2
Regional Voltage and Frequency:
480V, 60Hz
Content
This reference design - Engineering Package contains:
Reference Design 32.pdf
RD32_1.0_Cover_Sheet_EN_R0.pdf
RD32_1.1_Facility_Site_Layout_EN_R0.dwg
RD32_1.1_Facility_Site_Layout_EN_R0.pdf
RD32_2.1_Facility_Power_Overview_EN_R0.pdf
RD32_2.2_Elec_Oneline_EN_R0.dwg
RD32_2.2_Elec_Oneline_EN_R0.pdf
RD32_2.3_Facility_Power_EquipmentList_EN_R0.pdf
RD32_3.1_Facility_Cooling_Overview_EN_R0.pdf
RD32_3.2_Mech_Piping_EN_R0.dwg
RD32_3.2_Mech_Piping_EN_R0.pdf
RD32_3.3_Facility_Cooling_EquipmentList_EN_R0.pdf
RD32_4.1_IT_Space_Overview_EN_R0.pdf
RD32_4.2_IT_Space_EquipmentList_EN_R0.pdf
Scope of application
This reference design is applicable for:
Data Center IT Capacity:1045 kW
Adaptable from 200 kW to 3135 kW
Target availability:Tier 3
Annualized PUE at 100% Load:
1.53 in Miami, FL USA
1.31 in Montreal, Canada
1.39 in St. Louis, MO US
Total Racks and Average Density: 110 racks at 9.5 kW/rack
IT & Facility Floor Space: Min. 14970 ft2
Regional Voltage and Frequency:480V, 60Hz
Data Center IT Capacity:
Target availability:
Annualized PUE at 100% Load:
Total Racks and Average Density:
IT & Facility Floor Space:
Regional Voltage and Frequency: